电 话: +86-186 1118 5945 热 线: +86-138 3310 2548 邮 箱: balston@126.com Call : 1-800-343-4048 (U.K.) 网站:www.balston.com.cn
Global Analytical Gas Systems
Balston Zero Air Generators
It is well accepted in the field of gas chromatography that the purity of gases utilized for the operation of the gas chromatograph will affect the accuracy of analyses, consistency of results, detector sensitivity, and column life as well as column performance. As a result, it is important that sources of gas used by the chromatographer meet the demand to achieve higher sensitivities required for drug discovery, proteomics, genomics, environmental analysis, quality control procedures, government regulations, etc. Traditionally, high pressure compressed gas cylinders have been used to provide high purity gases; however, more recently, gas generators have become available as a source of high purity gases. A Zero Air Generator cam provide a source of ultra high purity grade zero air for combustion gas.
A Parker Balston Zero Air Generator will ensure a lower and more stable baseline signal when compared to traditional gase sources (i.e. cylinders). Due to lower baseline noise, the signal to noise ratio is larger, giving rise to high sensitivity or larger peak areas. A Parker Balston Zero Air Generators will produce ultra high purity zero grade air (<0.05 ppm THC) from an existing compressed air source. All that is required for installation is a standard compressed air line and an electrical outlet. A Parker Zero Air Generator is easy to operate, with no complicated operating procedures or labor intensive monitoring involved. A zero air generator allows the user to avoid the inconveniences and costs of cylinder gas supplies and dependence on outside vendors.
Features & Benefits |
|
欲了解更多Balston滤芯信息 请致电:186 1118 5945 或邮件 balston@126.com
型号 | 纯度 | 流量 | 工作压力 | 特性 | 产品名称 | CAD |
HPZA-18000 |
< 0.05 PPM THC |
UP TO 18 LPM | 100 PSIG | 零级空气发生器 | Y | |
HPZA-18000-220 | < 0.05 PPM THC | UP TO 18 LPM | 100 PSIG | 零级空气发生器 | Y | |
HPZA-18000EU | < 0.05 PPM THC | UP TO 18 LPM | 100 PSIG | 零级空气发生器 | Y | |
HPZA-18000JA-100 | < 0.05 PPM THC | UP TO 18 LPM | 100 PSIG | 零级空气发生器 | Y | |
HPZA-18000UK | < 0.05 PPM THC | UP TO 18 LPM | 100 PSIG | 零级空气发生器 | Y | |
HPZA-30000 | < 0.1 PPM THC | UP TO 30 LPM | 100 PSIG | 零级空气发生器 | Y | |
HPZA-30000-220 | < 0.1 PPM THC | UP TO 30 LPM | 100 PSIG | 零级空气发生器 | Y | |
HPZA-30000EU | < 0.1 ppm THC | 30 lpm | Y | |||
HPZA-30000JA-100 | < 0.1 PPM THC | UP TO 30 LPM | 100 PSIG | 零级空气发生器 | Y | |
HPZA-30000UK | < 0.1 PPM THC | UP TO 30 LPM | 100 PSIG | Y | ||
HPZA-3500 | < 0.05 PPM THC | UP TO 3.5 LPM | 100 PSIG | 零级空气发生器 | Y | |
HPZA-3500-220 | < 0.05 PPM THC | UP TO 3.5 LPM | 100 PSIG | 零级空气发生器 | Y | |
HPZA-3500EU | < 0.05 PPM THC | UP TO 3.5 LPM | 100 PSIG | 零级空气发生器 | Y | |
HPZA-3500JA-100 | < 0.05 PPM THC | UP TO 3.5 LPM | 100 PSIG | 零级空气发生器 | Y | |
HPZA-3500UK | < 0.05 PPM THC | UP TO 3.5 LPM | 100 PSIG | 零级空气发生器 | N | |
HPZA-7000 | < 0.05 PPM THC | UP TO 7 LPM | 100 PSIG | 零级空气发生器 | Y | |
HPZA-7000-220 | < 0.05 PPM THC | UP TO 7 LPM | 100 PSIG | 零级空气发生器 | Y | |
HPZA-7000EU | < 0.05 PPM THC | UP TO 7 LPM | 100 PSIG | 零级空气发生器 | Y | |
HPZA-7000JA-100 | < 0.05 PPM THC | UP TO 7 LPM | 100 PSIG | 零级空气发生器 | Y | |
HPZA-7000UK | < 0.05 PPM THC | UP TO 7 LPM | 100 PSIG | 零级空气发生器 | Y | |
VEM2000-30 | NA | 零级空气发生器 | N | |||
VEM6000 | < 0.1 ppm THC | 6lpm | 零级空气发生器 | N | ||
ZA10000 | < 0.1 ppm THC | 1lpm | 零级空气发生器 | N | ||
ZA10001 | < 0.1 ppm THC | 1lpm | 零级空气发生器 | N | ||
ZA10002 | < 0.1 ppm THC | 1 lpm | N | |||
ZA35000 | < 0.1 ppm THC | 3.5lpm | 零级空气发生器 | N | ||
ZA35001 | < 0.1 ppm THC | 3.5lpm | 零级空气发生器 | N | ||
ZA35002 | < 0.1 ppm THC | 3.5 lpm | 零级空气发生器 | N | ||
75-82EU | < 0.1 PPM THC | UP TO 650 CC/MIN | 100 PSIG | 防爆 | 零级空气发生器 | Y |
75-82EU-220 | < 0.1 PPM THC | UP TO 650 CC/MIN | 100 PSIG | 防爆 | 零级空气发生器 | Y |
75-82S | < 0.1 PPM THC | UP TO 1 LPM | 100 PSIG | 防爆 | 零级空气发生器 | Y |
75-82S-220 | < 0.1 PPM THC | UP TO 650 CC/MIN | 100 PSIG | 防爆 | 零级空气发生器 | Y |
75-82SJA-100 | < 0.1 PPM THC | UP TO 1 LPM | 100 PSIG | 防爆 | 零级空气发生器 | Y |
75-83-220 | < 0.1 PPM THC | UP TO 1 LPM | 100 PSIG | 零级空气发生器 | Y | |
75-83EU | < 0.1 PPM THC | UP TO 1 LPM | 100 PSIG | 零级空气发生器 | Y | |
75-83JA-100 | < 0.1 PPM THC | UP TO 1 LPM | 100 PSIG | 零级空气发生器 | Y | |
75-83NA | < 0.1 PPM THC | UP TO 1 LPM | 100 PSIG | 零级空气发生器 | Y | |
75-83UK | < 0.1 PPM THC | UP TO 1 LPM | 100 PSIG | 零级空气发生器 | Y | |
76-98-N100 | < 0.1 PPM THC | UP TO 5 SCFM | 100 PSIG | 零级空气发生器 | N | |
76-98-N200 | < 0.1 PPM THC | UP TO 10 SCFM | 100 PSIG | 零级空气发生器 | N |